 Guangdong Biolight Meditech Co., Ltd. China |
|
| | |
|
| Products Catalog: M900 vital sign monitor |
 (Product Photo) |
| Origin: | China |
| Price: | USD |
| Payment Method: | Telegraphic Transfer (T/T) |
| Pack. & Delivery: | carton |
| Specification: | Product Description
Used in hospital and clinique for monitoring patient' s NIBP, SPO2, PR, TEMP parameters
Product Feature
Easy button press, access all major functions rapidly
Bright, easy-to-read LED numerals
3-level audible and visual alarm
Removable & rechargeable battery
Digital SPO2, high capacity against interference of ESU, motion & low infusion
Isolated against defibrillation effect
Wireless or wire communicable with central station system
Integrated handle and full mounting solutions
Product Specification/ Models
Technical specifications
Safety: IEC60601 ( GB9706)
Dimension: 256mm ( W) x 209mm ( H) x 170mm( D)
Weight: 3.5 Kgs ( with battery)
Power Supply : 100~ 240V; AC: 47~ 63 Hz
12VDC
Patient Range: Adult, Pediatric and Neonatal
Display
LED: systolic, diastolic, mean pressure, SpO2, Pulse rate, temp.
4” FSTN LCD: Resolution: 320* 240
Indicator:
Alarm indicator
Battery indicator
Patient type indicator
Mute indicator
NIBP measuring indicator
Pulse quality indicator
NIBP
Method: Automatic oscillometric
Operation Modes: Singles ( manual) , Cycle ( automatic) , Rapid ( continuous)
Measurement : Systolic pressure/ diastolic pressure/ mean
Resolution: 1mmHg
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Accuracy: ± 3mmHg ( static)
Unit: mmHg / Kpa selectable
Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, 12 hours
Over-pressure protection: Yes
BLT Digital SPO2 ( Pulse Oximetry)
Range: 0-100%
Resolution: 1%
Accuracy: ± 2% ( 70% ~ 100% ) ;
± 3% ( 35% ~ 69% )
Unspecified ( 0~ 34% )
Pulse Rate:
Range : 25~ 250BPM
Resolution: 1 bpm
Accuracy: ± 1 bpm or ± 1% ( whichever is bigger)
TEMP
Range and Accuracy : 0~ 50 , ± 0.1 ( 25 ~ 50 )
Resolution : 1mmHg
Unit : Celsius, Fahrenheit
Alarm:
Level: 3-level, low, medium & high
Indication: sound and light
Setup: Default & Custom
Silence: all alarms can be silenced
Review
48 hours trend data
1200 groups of NIBP measuring data review
Environment Conditions:
Temperature:
Operation 0 -50
Storage / Transportation : -40 -70
Humidity:
Operation: 10% ~ 95% , noncondensing
Storage / Transportation : 0% ~ 93% noncondensing
Atmospheric Pressure:
Operation: 700~ 1060hPa,
Storage / Transportation : 500~ 1060hPa
Standard configuration
NIBP, SPO2, PR, TEMP, Battery
Option
Thermal Recorder, Nellcor SPO2
* Specification subject to be changed without notice |
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mr. Kevin Huang [Sales] |
| E-mail: |
kevin@blt.com.cn |
| Homepage: |
http://www.blt.com.cn |
| Instant Messaging |
|
| Phone Number: |
0086-756-3399905 |
| Fax Number: |
0086-756-3399911 |
| Address: |