Welcome to
Guangdong Biolight Meditech Co., Ltd.

Free Member
Guangdong Biolight Meditech Co.,  Ltd.
Guangdong Biolight Meditech Co., Ltd.
China
Home
Company Info
Products Catalog (11)
 
-  forehead thermometer
-  Looking for distributor
-  M6000C central monitoring system
-  BLT-1203B EKG machine
-  BLT-870 digital colposcope
-  M70 finger tip pulse oximeter
-  m700 handheld pulse oximeter
-  M900 vital sign monitor
-  M9000 patient monitor
-  m69 patient monitor
-  M7000 patient monitor
Share your thoughts
  - Write a review
- Recommend to your friends
Contact Us
Language
 - English
 Products Catalog: M9000 patient monitor
M9000 patient monitor
(Product Photo)
Origin:China
Price:USD
Payment Method:Telegraphic Transfer (T/T)
Pack. & Delivery:carton
Specification:Product Description
Used in hospital and clinique for monitoring patient' s ECG, RESP, NIBP, SPO2, TEMP, IBP, Multi-gas/ O2 parameters

Product Feature
12.1’ ’ LCD display, high resolution,
Large number display for long distance vision
Digital SPO2 technology offers anti-motion and anti-low perfusion funtions
Up to 66 beds network capacity to connect with HIS
168 hours tabular and graphic trends & data storage
Drug dose calculation
OXYCRG software
Bed to bed view

Product Specification/ Models
Technical specifications
Safety: IEC60601 ( GB9706)
Dimension: 318mm ( W) x 264mm ( H) x 152mm( D)
Power Supply : 100~ 240V; AC: 50~ 60 Hz
Alarm Indication: Visual and audible alarm
1800 groups of alarm events review
Application: Adult, Pediatric and neonate

ECG
Leads: I, II, III, aVR, aVL, aVF, V
Gains: 2.5mm/ mV, 5mm/ mV, 10mm/ mV, 20mm/ mV, 40mm/ mV, auto
Input impedance: e5M© ( d.c.~ 60Hz)
Common Mode Rejection Ratio: e85dB( diagnostic mode)
e105dB( monitoring & surgica mode)
Bandwith: 0.5-40Hz ( monitoring mode)
0.05-120Hz( diagnostic mode)
1-25Hz ( surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/ 60Hz
Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/ s, 25mm/ s, 50mm/ s
Heart Rate Range: 10-300BPM
Accuracy: ± 1BPM
ECG waveform playback: 30 minutes

NIBP
Method: Automatic oscillometric
Operation Modes: Singles ( manual) , Cycle ( automatic) , Rapid ( continuous)
Measurement : Systolic pressure/ diastolic pressure/ mean pressure
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Unit: mmHg / Kpa selectable
Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, hours
1000 groups of NIBP measuring data review

RESP
Method: Impedance Measurement
Measuring Range: 0-120bpm
Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
Apnea alarm: Available

BLT Digital SPO2 ( Pulse Oximetry)
Range: 0-100%
Accuracy: ± 2% ( 70% ~ 100% ) ;
± 3% ( 35% ~ 69% )
Unspecified ( 0~ 34% )
Range & Accuracy of Pulse Rate : 20~ 250BPM ± 1BPM

TEMP
Channel : 2 channels
Range : 0~ 50
Unit : Celsius, Fahrenheit
Resolution : 0.1
Accuracy : ± 0.1 ( 25 ~ 50 )
Alarm Range : 0~ 50

IBP
Channel : 2 channels
Range : -50~ 300 mmHg
Resolution : 1 mmHg
Accuracy : ± 2 mmHg ( ± 2% ) without probe
± 4 mmHg ( ± 2% ) with probe
Unit : mmHg , Kpa
Converter sensitivity: 5 uV/ V/ mmHg
Names of pressures: ART/ PA/ CVP/ LAP/ RAP/ ICP

EtCO2 ( side stream)
Method: Infrared spectrum
Range: 0.0-13.1%
Resolution : 1 mmHg ( 0.1% )
Accuracy : 5% EtCO2,

kevin@blt.com.cn  
Your inquiry will be recorded in "Member Trade Mail".

Recommend to your friends

Company Contact
   Name: Mr. Kevin Huang [Sales]
   E-mail: kevin@blt.com.cn
   Homepage: http://www.blt.com.cn   
   Instant Messaging
Y!: chshhuang1980 Y!: chshhuang1980
Windows Live: chshhuang@hotmail.com chshhuang@hotmail.com
Skype: kevinh1980
   Phone Number: 0086-756-3399905
   Fax Number: 0086-756-3399911
   Address: innovation first road,technology innovation coast zhuhai,CHINA 519085.
Zhuhai 519085, Guangdong
China


Want to build your own company website?
Please Click Here!